2 Commits
Author SHA1 Message Date
James Bateman (hp-laptop)andClaude Opus 4.8 ba1cd1ddcf Make the pump-1 1 W clamp overridable up to the 8000 mA protocol max
Adds a Pump Limit Override: the pump-1 current command is clamped to a
soft 4000 mA ceiling (the 1 W diode rating) by default, liftable to the
8000 mA hard protocol max only while the new amp_pump_override switch is
ON. Fail-safe: the override defaults OFF on every boot, and switching it
OFF immediately re-clamps a running setpoint back down to 4000 mA so the
booster cannot stay parked above 1 W. The HA pump-1 number now spans
0..8000 mA; values above 4000 take effect only with the override on.

PUMP_CURRENT_MAX_MA is split into PUMP_CURRENT_SOFT_MAX_MA (4000) and
PUMP_CURRENT_HARD_MAX_MA (8000). README/BOM updated. Builds clean
(flash 59.3%); not yet flashed (ESP32 needs USB, no OTA).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-10-02 14:21:56 +01:00
James Bateman (hp-laptop)andClaude Opus 4.8 ffadf4b37b Add bill of materials; link it from the README
Full parts list to rebuild the MOPA: seed (DFB1550LP + CTL200 + its
5.9 V/3 A supply), Agiltron M511 EYDFA booster + v1.10 adaptor board,
ESP32 bridge, fibre/attenuator/output-connector optics, and the 3V3
signal wiring table. Electrical specs not firmly in the lab notes are
flagged to confirm from the datasheet.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
2026-10-02 13:34:16 +01:00